ATEX Pressurized enclosure Ex px - zone 1 / Ex p - zone 21 Serie FS850S

Explosionproof control unit Ex p FS850S:

  • compact
  • intelligent
  • economic

More information in the document "EX-PRESS pressurized enclosures Exp".

FS850S.0.0.1.W.TF, FS850S.0.2.1.W.TF, FS850S.0.4.1.W.TF, FS850S.0.6.1.W.TF, FS850S.0.8.1.W.TF, FS850S.6.0.1.W.TF, FS850S.6.2.1.W.TF, FS850S.6.4.1.W.TF, FS850S.6.6.1.W.TF, FS850S.6.8.1.W.TF
Show photo

General technical specifications

Protection IP65, without outlet drill
Material aluminium RAL7035
EEx p configuration (parameter input) LC-Display, menu guided (different languages: German, English, French and Dutch)
Storage (memory) by EEPROM double saved
Pneumatic pressure range 0 ... 18 mbar
Switching capacity • AC: U ≤ 250VAC, l ≤ 5A at cos φ > 0,7
• DC: U ≤ 30VDC, l ≤5A, P ≤ 150W
Control circuits intrinsically sasfe Ex ib IIC (for further details see DMT 99ATEXE003)
Consumption ca. 2,5VA without peripherals
Mounting position • position independent
• only intake and outlet of the control unit should be lined up on a horizontal axis
Ambiant temperature • -20°C - +45°C (T6)
• -20°C - +60°C (T4)
Guideline ATEX
Manufacturer Ysebaert - Gönnheimer
Suited for
Zone 1 Zone 2
Zone 21 Zone 22

Classification

  • II 2 G Ex e mb [ib] [px] IIC T4/T6 Gb
  • II 2 D Ex tb [ib] [p] IIIC T70°C Db IP65

Zone

0 1 2
20 21 22

Ordering data (click on the order reference for more details)

Order refer. Voltage Plate orifice in mm Range in m³/h
FS850S.0.0.1.W.TF 230VAC 4 0,5 ... 1,1
FS850S.0.2.1.W.TF 230VAC 6 1,1 ... 2,7
FS850S.0.4.1.W.TF 230VAC 10 2,5 ... 6,5
FS850S.0.6.1.W.TF 230VAC 14 6,0 ... 11,0
FS850S.0.8.1.W.TF 230VAC 18 9,0 ... 15,0
FS850S.6.0.1.W.TF 24VDC 4 0,5 ... 1,1
FS850S.6.2.1.W.TF 24VDC 6 1,1 ... 2,7
FS850S.6.4.1.W.TF 24VDC 10 2,5 ... 6,5
FS850S.6.6.1.W.TF 24VDC 14 6,0 ... 11,0
FS850S.6.8.1.W.TF 24VDC 18 9,0 ... 15,0

On request

  • 24VAC, 42VAC, 110VAC, 120VAC